This paper illustrates the problems faced after the sudden failure of process gas transfer line connected to Secondary reformer. During the emergency repair it was extremely difficult to carry out refractory repair and installation of SS321 liners due to space constraint. Remedial action of insitu refractory repair and SS321 liner was taken up by using simple innovative methods to save time and effort. This resulted in enhanced safety and reliability of operations till new transfer lines are procured and installed.
机译:本文说明了连接到二级重整器的过程气体传输线突然失效后面临的问题。在紧急修复期间,由于空间约束,在SS321衬里进行耐火修复和安装是极其困难的。通过使用简单的创新方法来节省时间和努力,通过简单的创新方法来储存Insitu耐火修复和SS321衬里的补救措施。这导致操作的安全性和可靠性,直到采购和安装新的传输线。