INTRODUCTION: The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. METHODS: Four previously trained men (mean ± SD; age = 20±2 years, body mass = 99±18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. RESULTS: The pneumatic resistance GRF (N; mean ± SD) was 749±114 on the left leg and 786±123 on the right leg and the free weight GRF was 786±114 left and 861±111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. CONCLUSION: Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.
机译:简介:卸载空间导致骨骼和肌肉萎缩,气动电阻深蹲运动对策具有以下可能在轻质和紧凑的配置中提供优化的可控电阻。然而,所提出的装置中的杠铃的每个端部连接到单独的电阻滚筒,这可能导致双侧不对称负载。因此,该研究的目的是与自由重量相比,将新蹲下装置的单侧地面反作用力(GRF)进行比较。方法:四种先前培训的男性(平均±SD;年龄= 20±2年,体重= 99±18千克)进行三组三次重复的最大耗尽蹲便器,气动控制恒定电阻和自由重量,每个都具有电阻水平设定为每个主题的体重的一半。在每只脚下的力板上测量每个升降模型的单侧GRF数据,以每只脚下的力板测量。结果:气动电阻GRF(n;平均值±Sd)在左腿上为749±114,右腿786±123,自由重量GRF为786±114,861±111右偏差为5%左右GRF与气球和9%的自由重量差异。左右GRF之间的相关系数为0.92,气动率为0.80,自由重量为0.80。结论:由于气动装置引起比传统的自由重量更加双侧对称的GRF,因此独立电阻缸是可接受的设计配置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号