An empirical model of end-of-life performance data is used in a monte-carlo analysis to evaluate the current distribution across parallel current paths of a power module. It was shown how the expected distributions of current and voltage drop provide a method to de-rate the maximum current rating of contacts used in multi-path power applications. A number of new ideas were introduced in this paper. First, the end-of-life resistance data was used in conjunction with a monte-carlo analysis. This provided an empirically based model to determine the expected current and voltage variations. In addition, the concept of voltage drop change was applied as an end-of-life criteria to validate the maximum current rating of individual contacts. It is believed, the combined use of these concepts provides a technical basis for making decisions on current de-rating and the number of contacts needed to safely split the total current over multiple current paths.
机译:寿命终端性能数据的经验模型用于蒙特卡罗分析,以评估电源模块的并行电流路径跨越电流分布。显示了电流和电压降的预期分布如何提供一种方法来解除多路径电源应用中使用的触点的最大电流额定值的方法。本文介绍了一些新的想法。首先,终生抗性数据与蒙特卡罗分析结合使用。这提供了一个基于凭证的模型来确定预期的电流和电压变化。此外,将电压降的概念施加为寿命终端标准,以验证各个触点的最大电流等级。据信,这些概念的结合使用为制定电流解鉴定的决定以及安全地分配多个电流路径上的总电流所需的触点数量提供技术依据。