The efficiency and reliability of hermetic reciprocating compressors adopted for household refrigeration are affected by the temperature distribution of their components. Simulation models developed to assist the thermal design of compressors require heat transfer coefficients in different components, usually estimated from correlations available for simplified geometries. However, the geometries of some components are complex and require more representative heat transfer coefficients. This paper presents experimental results for heat transfer coefficients obtained from measurements of heat flux and temperature in different regions of the suction muffler of a small reciprocating compressor under different operating conditions. A least square method was employed to obtain correlations for local heat transfer coefficients, which were then compared with estimates given by correlations available in the literature for simplified geometries.
机译:用于家庭制冷采用的密封往复式压缩机的效率和可靠性受其组分温度分布的影响。开发用于协助压缩机的热设计的仿真模型需要在不同组件中的传热系数,通常从可用于简化几何形状的相关性估计。然而,一些组分的几何形状是复杂的并且需要更多代表性的传热系数。本文介绍了在不同的操作条件下,从小往复式压缩机的抽吸消声器的不同区域中的热通量和温度测量获得的传热系数的实验结果。使用最小二乘法以获得局部传热系数的相关性,然后将其与文献中可用的相关性用于简化几何形状的相关性进行比较。