The objective of this work was to compare indoor and outdoor concentrations of fine particulate organic carbon (OC) and elemental carbon (EC), determined from undenudcd quartz filters. PM_(2.5) samples were collected in Seattle at a central site and indoors and outdoors at private residences between February 22 and May 25, 2000, and analyzed for OC and EC content. Indoor and outdoor denuded quartz filters were also analyzed for OC and EC, Indoor OC sampled onto undenuded quartz filters was typically higher than outdoor OC, while outdoor EC was higher than indoor EC. For denuded quartz filters, the indoor OC was not typically higher than the outdoor OC. Indoor OC mass collected on an undenuded quartz fiber filter frequently exceeded the PM_(2.5) mass collected on a Teflon filter. This anomaly results from a positive sampling artifact from the adsorption of semi-volatile organic components from the vapor phase onto quartz filters.
机译:这项工作的目的是比较由非义义务石英过滤器确定的细颗粒有机碳(OC)和元素碳(EC)的室内和室外浓度。 PM_(2.5)样本在西雅图,在3月22日和2000年5月25日至5月25日之间的私人住宅,并分析了OC和EC含量的私人住院。对于OC和EC,还分析室内和室外裸露的石英过滤器,在未鉴定的石英过滤器上采样的室内OC通常高于室外OC,而户外EC高于室内EC。对于裸露的石英滤波器,室内OC通常不高于室外OC。收集在无所得的石英纤维过滤器上的室内OC质量经常超过在Teflon过滤器上收集的PM_(2.5)质量。这种异常从将半挥发性有机组分从气相吸附到石英过滤器中的正面取样伪影产生。