In practice the commonly used criteria for thermal comfort in Dutch buildings (weighted factor method) often lead to confusion. The criteria are hard to understand for non-experts, and many doubt the validity of the present criteria. A project was initiated in order to formulate alternative ways to predict, evaluate and communicate thermal comfort performance of buildings. The result: a draft version for a new Dutch guideline for design and evaluation purposes. Properties of the new guideline are: 1. It distinguishes between requirements for centrally controlled and for occupant controlled indoor environments. 2. Limits are set in terms of maximum allowable operative indoor temperatures. These increase with increasing average outdoor temperature, anticipating on adaptation effects. 3. A building's performance is characterized by '% of working time that the allowable (floating) maximum indoor temperature is exceeded' and the 'average amount of degrees that the upper-limit is exceeded during those exceeding hours'.
机译:在实践中,荷兰建筑物(加权因子法)中的热舒适性的常用标准通常会导致混淆。标准很难理解非专家,许多人怀疑目前标准的有效性。启动项目以制定预测,评估和传达建筑物的热舒适性能的替代方法。结果:新荷兰语指南的设计和评估目的的草案。新指南的属性是:1。它区分集中控制和乘员控制的室内环境的要求。 2.限制在最大允许的操作室内温度方面设定。随着平均室外温度的增加,预期适应效果增加。 3.建筑物的性能的特点是“工作时间的百分比,允许的(浮动)最大的室内温度超过”并且“超过时间超过上限的平均度数”。