首页> 外文会议>European workshop on structural health monitoring >Study of the Interaction Between Bonded Piezo-Electric Devices and Plates
【24h】

Study of the Interaction Between Bonded Piezo-Electric Devices and Plates

机译:粘合压电件与板相互作用的研究

获取原文

摘要

Thin and small piezo-electric discs may be used in health-monitoring systems for composite plates. Before using them in actual systems, it is needed to prove that they do not initiate delaminations and that they are not damaged by service loadings, in particular fatigue loadings. Experiments has been done showing that if they are sufficiently small and thin, the compressive strength is not modified and that they can sustain cyclic fatigue loadings. Moreover, it is proved that the electric impedance of bonded disc can be use to check the quality of the bonding between the host structure and the discs.
机译:薄型和小型压电盘可用于复合板的健康监测系统。在在实际系统中使用它们之前,需要证明它们不会启动分层,并且它们不会被服务载荷损坏,特别是疲劳负载。实验已经表明,如果它们足够小且薄,则不会改变抗压强度,并且它们可以维持循环疲劳载荷。此外,证明了粘合盘的电阻抗可用于检查宿主结构和盘之间的键合的质量。