In order to elucidate the effects of housing types on aerosols and bacteria concentration, the aerosols and bacteria concentration were measured in an enclosed type dairy milking free stall house and an open type free barn milking house. Aerosol concentrations was measured by Optical Particle Sizer (OPS). Aerobacterias were collected using a Coriolis fi Air Sampler. The samples then inoculated into medium for detection of Staphylococcus aureus, Escherichia coli and total Aerobic bacteria. The averageconcentration of particle sizes 0.3-0.5 [im, 0.5-1.0 fim, 1.0-2.0 nm, 2.0-5.0 /im and 5.0-10.0 /im in the enclosed house were 7.96, 6.94, 5.97, 5.76, 4.91 logioparticles/m3, respectively and in the open house were 7.84, 6.75, 5.85, 5.71, 5.11 logio particles/m3, respectively. There was no significance difference of aerosols concentration (p>0.05) between enclosed house and open house. The average concentration of Staphylococcus aureus, Escherichia coli and total Aerobic bacteria in enclosed house were2.04, 0.04, 2.91 logio cfu/m3, respectively and in open house were 2.87, 0.76, 3.96 logio cfu/m3, respectively. There was a 1% significant difference for Staphylococcus aureus (p<0.01), 5% for Escherichia coli (p<0.05) and 1% for Aerobic bacteria (p<0.01) between enclosed house and open house. The difference of bacteria concentration between enclosed and open houses were due to difference of airflow within the houses (p<0.01). In enclosed and open houses there was no correlation between aerosol concentration and bacteria concentration.
机译:为了阐明壳体类型对气溶胶和细菌浓度的影响,在封闭式乳制品免费房屋和开放式免费谷仓挤奶房中测量气溶胶和细菌浓度。通过光学粒子Sizer(OPS)测量气溶胶浓度。使用科里奥利纤维采样器收集有氧刺激。然后将样品接种到培养基中,用于检测金黄色葡萄球菌,大肠杆菌和总食细菌。粒度为0.3-0.5 [IM,0.5-1.0 FIM,1.0-2.0 nm,2.0-5.0 / IM和5.0-10.0 / IM和5.0-10.0 / IM的封闭房屋为7.96,6.94,5.97,5.76,4.91 logioparticles / m3,分别和开放式房屋分别为7.84,6.75,5.85,5.71,5.11 Logio颗粒/ M3。封闭房屋和开放式房屋之间的气溶胶浓度(p> 0.05)没有显着性差异。封闭房屋中金黄色葡萄球菌,大肠杆菌和总食细菌的平均浓度分别为2.04,0.04,2.91 LogiO CFU / M3分别为2.87,0.76,3.96 LogiO CFU / M3。金黄色葡萄球菌(P <0.01)的含量显着差异为1%,对于大肠杆菌(P <0.05),有氧细菌(P <0.01)在封闭房屋和开放房屋之间的1%。封闭和开放式房屋之间的细菌浓度差异是由于房屋内的气流差异(P <0.01)。在封闭和开放的房屋中,气溶胶浓度与细菌浓度之间没有相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号