Pilot scale tests were conducted for simultaneous removal of NOx and SO_2 from coal boiler flue gases by corona discharge induced ammonia radical injection techniques, i.e. the corona radical shower system. Tests were conducted for the flue gas rate from 1000 to 1500 Nm~3/h, the gas temperature from 62 to 80°C, the ammonia-to-total acid gas molecule ratio from 0.88 to 1.3, applied voltage from 0 to 25 kV and NO initial concentration from 53 to 93 ppm for a fixed SO_2 of 800 ppm. The results show that SO_2 removal increases with increasing ammonia radical injection rate and non-monotonically depends on in-put electrical power. The NOx removal increases with increasing in-put electrical power and ammonia radical injection rate. Approximately 9 kg of SO_2 were removed by 1 kWh of energy input with 99% of SO_2 removal, while approximately 125 g of NOx was removed by 1 kWh of energy input with 75% of removal efficiency.
机译:通过电晕放电诱导的氨自由基注射技术,进行导频测量试验以同时除去煤锅炉烟气中的NOx和SO_2,即电晕自由基淋浴系统。对烟道气速率为1000至1500nm〜3 / h的试验,气体温度从62〜80℃,氨 - 总酸气体分子比为0.88至1.3,施加电压为0至25 kV并且没有53至93ppm的初始浓度,固定的SO_2为800ppm。结果表明,随着氨的自由基喷射速率的增加,脱离所拆除增加,并且非单调依赖于放入电力。随着放入电力和氨自由基喷射率的增加,NOx去除增加。通过1千瓦时除去大约9kg的SO_2,其中99%的SO_2去除,而1kWH的能量投入量均以75%的去除效率取出约125g NOx。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号