首页> 外文会议>International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings >Analysis of the energy and thermal performance of a radiant cooling panel system with integrated phase change materials in very hot and humid conditions
【24h】

Analysis of the energy and thermal performance of a radiant cooling panel system with integrated phase change materials in very hot and humid conditions

机译:辐射冷却面板系统的能量和热性能在非常热湿润的条件下具有集成相变材料的辐射冷却面板系统

获取原文

摘要

This study evaluates the energy and thermal perfonnance of a radiant cooling panel system with integrated phase change materials (PCMs) for application in building retrofit projects. The focus is on the energy saving potential of using two different strategies to avoid condensation in very hot and humid climate conditions. The cooling energy consumption of a DOE medium office prototype building model with a conventional all-air system is used as a baseline for comparing the proposed configurations. The results show that the radiant system yielded energy savings of around 48% compared to the all-air system for existing office buildings. Results also show that the proposed system is able to operate only during the night-time, which improves the plant efficiency. Thus, the energy savings are mainly due to a reduction in the energy consumption of the cold generation system and lower energy use for ventilation compared with conventional air systems.
机译:本研究评估了具有集成相变材料(PCM)的辐射冷却面板系统的能量和热线,以便在建筑改装项目中应用。重点是使用两种不同策略来避免在非常热和潮湿的气候条件下凝结的节能潜力。用传统的全空气系统的DOE介质办公原型建筑模型的冷却能耗用作比较所提出的配置的基线。结果表明,与现有办公楼的全空气系统相比,辐射系统产生的节能约为48%。结果还表明,所提出的系统能够在夜间运行,这提高了工厂效率。因此,能量节省主要是由于冷发射系统的能量消耗降低,与传统的空气系统相比,通风的能量消耗降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号