Comparison of experimental techniques for determination of stray capacitances in high frequency transformers

机译:高频变压器中杂散电容测定的实验技术比较

获取原文

摘要

A new approach for experimental determination of stray capacitances in high frequency transformers is proposed in this paper. This approach identifies the stray capacitances of a two winding transformer by conducting open and short circuit tests on both windings within the range of normal operation frequencies and fitting the /spl pi/-shaped capacitor network model to the voltage and current readings. The experimental results of the stray capacitances in a 500 W two foil winding soft ferrite E-core high frequency transformer obtained by this two port network approach are compared with those obtained by the forced resonance and the step response approaches previously proposed by the authors. The merits and drawbacks of these approaches are also discussed.
机译:本文提出了一种新方法,用于实验测定高频变压器中杂散电容的杂散电容。该方法通过在正常操作频率范围内的绕组内进行开放和短路测试并将/ SPL PI /叠加电容网络模型进行打开和短路测试来识别两个绕组变压器的杂散电容,并将/ SPL PI /形电容网络模型拟合到电压和电流读数。通过这种港口网络方法获得的500W两个箔绕组软铁氧体E核高频变压器中的杂散电容的实验结果与由强制共振获得的那些,以及提交人提出的阶梯响应方法。还讨论了这些方法的优点和缺点。