This paper describes the results of dynamic and static load testing at a site where open-ended steel tube piles were driven into a dense to very dense sand layer. The pile capacities on driving were significantly less than anticipated from the design calculations, with shaft resistances of 5 to 20kPa measured even at 40m depth. Later testing confirmed development of shaft resistances in excess of 150kPa. A mechanism of pile whip or flexure is hypothesized. Resistance from the internal soil column was also investigated.
机译:本文介绍了在将开放式钢管桩被驱动成致密的砂层的场地上动态和静态负荷测试的结果。驾驶桩的容量明显低于设计计算的预期,轴电阻为5至20kPa,即使在40m深度下也会测量。后来测试证实了轴电阻超过150kPa的开发。桩鞭状或挠曲的机制是假设的。还研究了来自内部土柱的抗性。