One of the critical points, when the reliable operation of water-cooled generator is concerned, is the mechanical integrity of stator windings. The resonance of stator winding will occur when the intrinsic frequency of each stator winding equals or closes to excitation frequency, 120Hz, due to an electromagnetic force which occurs always during the normal operation. This resonance may cause the leak of cooling water and I or the life reduction of generator stator due to the high cycle fatigue crack. This paper describes the modeling of generator stator end windings for analysis of the winding vibration behaviors. The result of the analysis has a good agreement with that of field test. A mechanical diagnostic method is also suggested and applied to 500MW water-cooled generator stator in order to evaluate the mechanical integrity of stator end windings in power plant. It was found that the vibration characteristics of poor windings in terms of resonance possibility could be improved through the blocking of end windings.
机译:当涉及水冷发电机的可靠运行时,这是一个关键点是定子绕组的机械完整性。当每个定子绕组的固有频率等于或关闭到激发频率,120Hz时,将发生定子绕组的共振,由于在正常操作期间发生的电磁力。由于高循环疲劳裂纹,该共振可能导致冷却水和I的泄漏或发电机定子的寿命减少。本文介绍了发电机定子端绕组的建模,用于分析绕组振动行为。分析结果与现场测试吻合良好。还提出了一种机械诊断方法并将其应用于500MW的水冷发电机定子,以评估电厂中定子端绕组的机械完整性。结果发现,通过阻塞端绕组可以改善谐振可能性不良绕组的振动特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号