首页> 外文会议>Power Sources Conference >Safety evaluation of lithium-ion batteries
【24h】

Safety evaluation of lithium-ion batteries

机译:锂离子电池的安全评估

获取原文

摘要

Little data exists in the public domain fi)r lithium-ion batteries that have encountered prolonged cycling and operation at high rates and high temperatures.Six UR18650 lithium-ion cells were continuously charged/discharged at a constant temperature of 50°C at currents of 3.2A, 2.6A or l.3A charge and discharged at 1.3W to a capacity cutoff of 65mAh. No cells showed any venting, fire or bulging during orafter the tests.The amount of hydrogen, was measured by placing chips scraped from the negative electrode in water. The amount of hydrogen from the "as received" and cells after completion of cycling was less than 15 I/kg/hr. However, the amount of hydrogen evolved fromthe negative electrode of fully charged cells was as high as 87.4 l/kg/hr.Two fully charged cells were subjected to the DoT nail penetration test. No venting, fire or explosion we observed.
机译:在公共领域FI)中存在的少量数据在高速率和高温下遇到长期循环和操作的锂离子电池。将UR18650锂离子电池在50℃的恒定温度下连续充电/放电3.2a,2.6a或l.3a充电并以1.3w放电到65mah的容量截止值。在测试期间,没有细胞显示出任何通风,火或凸出。通过将从负电极中的碎片放入水中来测量氢气量。从循环完成后,从“如所接受”和细胞的氢量小于15I / kg / hr。然而,从完全带电细胞的负极演化的氢量高达87.4L / kg / hr.two完全带电细胞进行点指甲渗透试验。我们观察到没有通风,火灾或爆炸。