More than ten of in-vacuum type insertion devices are installed in the SPring-8 storage ring. When their gap was closed, we observed the low frequency vertical coupled bunch instability. We consider that this instability is driven by resistive-wall impedance caused by the magnet blocks made of NdFeB, of which conductivity is two order lower than Aluminum. We calculated the resistive-wall impedance and measured its characteristics.