Lightning impulse experiments on 220 kV composite insulator and its parallel gap devices with different distances under standard lightning impulse were carried out at the high altitude area of 2000 m while their voltage-time (v-t) Characteristic investigated. The v-t curves, drawn by the experimental data, demonstrate that all the v-t curves with the implement of the parallel gap devices are lower than that of the standard 220 kV composite insulator. Based on the insulation coordination principle, this paper recommends the maximum protective distance of the parallel gap device at the high altitude area of 2000 m. Moreover, the flashover records indicate that the parallel gap device drives the arc far away from the insulator and fixes the position of the burning arc.
机译:在220kV复合绝缘子上的避雷脉冲实验及其在标准闪电脉冲下具有不同距离的平行间隙装置,在2000米的高空区域进行,虽然其电压 - 时间(V-T)特性进行了研究。通过实验数据绘制的V-T曲线证明了具有平行间隙装置的实现的所有V-T曲线低于标准220kV复合绝缘体的所有V-T曲线。基于绝缘配位原理,本文建议平行间隙装置在2000米的高海拔地区的最大保护距离。此外,闪络记录表明并联间隙装置将弧远离绝缘体的弧形驱动并固定燃烧弧的位置。