A large-scale in-situ experiment was conducted in Kamaishi mine. The major objectives of this thermo-hydro-mechanical (T-H-M) test at Kamaishi mine were to evaluate applicability of the engineered barrier technology, to observe near field coupled T-H-M phenomena in situ and to increase the confidence of coupled T-H-M models. The test pit with a diameter of 1.7 m and a depth of 5.0 m was excavated at the floor of drift. The heater was composed of heater frame with a diameter of 1.04 m and a height of 2.0 m and electric heater that was installed in the heater frame. The heater was placed in the center of the pit and buffer material was compacted around the heater at the field. The duration of heating phase was 250 days and that of cooling phase was 180 days. The heater surface was controlled to be 100°C during the heating phase. A number of sensors were installed in both buffer and rock mass during the test. The field experiment leads to a better understanding of the behavior of the T-H-M phenomena in the near field. JNC developed T-H-M model to evaluate the phenomena in the unsaturated buffer. Comparison between measurements and predictions showed good agreement.
机译:一个大型的现场实验是在釜石矿山进行。在釜石这个热 - 水 - 机械(T-H-M)测试的主要目的雷人评价工程屏障技术的适用性,观察近场耦合牛逼-H-M现象在原地,并增加加上T-H-M车型的信心。的直径为1.7米到5.0米的深度测试凹坑在漂移的地板被挖掘。加热器是由加热器帧的一个直径1.04米和2.0米的高度和电加热器被安装在加热器框架。加热器被放置在坑的中心,缓冲物质周围在该领域的加热器压实。加热阶段的持续时间为250天,即冷却阶段的是180天。加热器表面被控制在加热阶段为100℃。多个传感器被安装在测试期间既缓冲器和岩体。田间试验导致更好地了解在近场的T-H-M现象的行为。 JNC开发T-H-M型,以评估在所述不饱和缓冲液中的现象。测量和预测之间的比较显示较好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号