A capillary pumped loop (CPL) with a single starter pump in its evaporator section has been demonstrated to have very reliable start-ups and robust operation. In order to service payloads with large thermal footprints or to service multiple payloads, a CPL with multiple starter pumps seems a logical approach. However, questions were raised concerning its reliability for successful start-ups. In order to verify the feasibility of such a concept, a test program was conducted at NASA Goddard Space Flight Center, using four starter pumps plumbed in parallel. The main purpose of this experimental investigation was to verify the system's ability to provide a successful start-up and to retain performance characteristics demonstrated by a CPL with multiple evaporators of the traditional two-port pump design. Tests were conducted progressively by installing one, two and four pumps in the test loop. Experimental results indicated that the loop operated very reliably after a successful start-up had been established. The system always started successfully when it contained only one or two starter pumps. However, some unsuccessful start-ups were encountered when four pumps were plumbed in parallel.
机译:已经证明了一种具有单个起动泵的毛细管泵送环(CPL),以具有非常可靠的启动和鲁棒操作。为了使用大型热占地面积或使用多个有效载荷的有效载荷,具有多个启动泵的CPL似乎是一种逻辑方法。但是,提出了关于其成功初创企业的可靠性的问题。为了验证这种概念的可行性,在美国宇航局戈达德航天飞行中心进行了一项测试计划,使用四个起动泵并联。该实验调查的主要目的是验证系统提供成功启动的能力,并保留CPL和传统的双端口泵设计的多个蒸发器所示的性能特征。通过在测试回路中安装一个,两个和四个泵进行逐步进行测试。实验结果表明,在建立成功启动后,环路非常可靠地运行。当它仅包含一个或两个启动泵时,系统始终成功开始。然而,当四个泵并联时,遇到了一些不成功的初创企业。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号