This paper describes the failure analysis methods used to characterize micro cracks that resulted in laser vias of printed circuit boards (PCBs) through case studies of destructive failure analysis. Defects such as cracks in laser vias of PCBs can cause open or low leakage failure mode of module due to improper cleaning during the PCB process, natural oxide films such as brown oxide, or physical forces by use. Therefore, it's difficult to identify the causes of these phenomena unless proper analytical techniques are used. In this study, multiple analytical techniques are employed to characterize micro cracks in laser vias. The destructive analysis with cross section and ion milling process is used to detect and inspect an accurate micro crack phenomenon of laser via. The characterization analysis using TEM, EDX and SIMS equipment after separating laser vias from a PCB is used to analyze failure cause of micro crack in laser via. This paper will be concluded with a discussion about what physical analysis methods should be used to analyze the causes of micro cracks for laser vias of PCBs.
机译:本文介绍了用于表征用于表征导致印刷电路板(PCB)激光通孔的微裂纹的故障分析方法,通过对破坏性故障分析的情况研究。由于PCB工艺期间的清洁不当,诸如棕色氧化物(如棕色氧化物)或物理力的自然氧化膜,或者通过使用,PCB激光通孔中的裂缝等缺陷可能导致模块的开放或低泄漏故障模式。因此,除非使用适当的分析技术,否则难以识别这些现象的原因。在该研究中,采用多种分析技术在激光通孔中表征微裂纹。使用横截面和离子铣削过程的破坏性分析用于检测和检查激光通孔的精确微裂纹现象。使用TEM,EDX和SIMS设备在从PCB分离后使用TEM,EDX和SIMS设备的表征分析用于分析激光通孔中微裂纹的故障原因。本文将讨论讨论应使用哪种物理分析方法来分析PCB激光通孔的微裂纹的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号