A simulation study of unwhitened versus whitened EMG amplitude estimation

机译:无电影与美白EMG幅度估计的模拟研究

获取原文

摘要

Amplitude estimates of simulated surface electromyograms (EMGs) were studied using both unwhitened and whitened EMG amplitude estimators. Constant-effort non-fatiguing EMGs were simulated as the superposition of simple synthetic motor unit action potential trains (MUAPTs). Each MUAPT was formed from random firings of randomly shaped motor unit action potentials. Two aspects of unwhitened vs. whitened amplitude estimators were studied: (1) the relationship between the mean value of the EMG amplitude estimate vs. the level of contraction and (2) the signal-to-noise-ratio (SNR) performance of the EMG amplitude estimate. It was found that the relationships between estimated EMG amplitude vs. MUAPT firing rate and the number of MUAPTs were not altered by whitening. However, the performance of whitened amplitude estimators was markedly better. These results suggest that whitening can provide a higher fidelity EMG amplitude estimate without distorting the relationship between EMG and the mechanical output of the muscle.
机译:使用无机和变白的EMG幅度估计器研究了模拟表面电谱(EMG)的幅度估计。恒定的非疲劳EMG被模拟为简单的合成电机单元动作潜在列车(MUAPTS)的叠加。每个MuATT由随机形状电机单元动作电位的随机燃烧形成。没有研究过的与白化幅度估计器的两个方面:(1)EMG幅度估计与收缩水平的平均值与(2)的信噪比(SNR)性能之间的关系emg幅度估计。结果发现,估计的EMG幅度与射击率之间的关系和猝灭率的关系并没有通过美白而改变。然而,美白幅度估计器的性能显着更好。这些结果表明,美白可以提供更高的保真度EMG幅度估计,而不会扭曲EMG与肌肉的机械输出之间的关系。