首页> 外文会议>International Conference on Environmental Systems >Geoscience Laser Altimeter System (GLAS) Loop Heat Pipes: An Eventful First Year On-Orbit
【24h】

Geoscience Laser Altimeter System (GLAS) Loop Heat Pipes: An Eventful First Year On-Orbit

机译:地球科学激光高度计系统(GLAS)环热管:最终的第一年轨道

获取原文

摘要

Goddard Space Flight Center's Geoscience Laser Altimeter System (GLAS) is the sole scientific instrument on the Ice, Cloud and land Elevation Satellite (ICESat) that was launched on January 12, 2003 from Vandenberg AFB. A thermal control architecture based on propylene Loop Heat Pipe technology was developed to provide selectable/stable temperature control for the lasers and other electronics over the widely varying mission environment. Following a nominal LHP and instrument start-up, the mission was interrupted with the failure of the first laser after only 36 days of operation. During the 5-month failure investigation, the two GLAS LHPs and the electronics operated nominally, using heaters as a substitute for the laser heat load. Just prior to resuming the mission, following a seasonal spacecraft yaw maneuver, one of the LHPs deprimed and created a thermal runaway condition that resulted in an emergency shutdown of the GLAS instrument. This paper presents details of the LHP anomaly, the resulting investigation and recovery, along with on-orbit flight data during these critical events.
机译:戈达德太空飞行中心的地球科学激光高度计系统(GLAS)是2003年1月12日起推出的冰,云和陆海拔卫星(ICESAT)的唯一科学仪器来自南方堡AFB。开发了一种基于丙烯回路热管技术的热控制架构,为在广泛变化的任务环境中为激光器和其他电子提供选择/稳定的温度控制。在标称LHP和仪器启动之后,特派团在仅36天的操作之后,首次激光的故障被中断。在5个月的故障调查期间,两个GLAS LHP和电子产品名义上运行,使用加热器作为激光热负荷的替代品。正要在恢复任务后,遵循季节性航天器偏航机动,其中一个LHPS脱离并产生了一种导致GLAS仪器紧急停机的热失控条件。本文介绍了LHP异常,由此产生的调查和恢复以及在这些关键事件中的轨道飞行数据的详细信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号