Two air quality monitors (AQMs) were launched to the International Space Station (ISS) in March 2013. The AQM units, with different gas chromatographic columns, operate simultaneously on the ISS to accurately measure target compounds important to the assessment of the onboard air quality. The AQMs had to be validated, which meant they had to demonstrate their ability to accurately analyze target compounds in the ISS atmosphere, before they could be proclaimed ready for operational use. As the name implies, operational hardware can and will be used to make real-time decisions; therefore validation is necessary to have confidence in generated data. The AQMs were deployed in late March 2013 and validation was begun in May 2013. During the in-flight validation phase, a minimum of 6 mini-grab sample containers (mini-GSCs) were acquired nearly simultaneously with the AQM sample analysis. Six months was needed to acquire the necessary mini-GSC-AQM pairings to complete validation. The validation criteria, established prior to launching the AQMs, were applied to each compound and not to the AQM units. Furthermore, the validation included the checkout of the AQM battery operations in a remote location. The AQMs operate autonomously using a scripted analysis scheme and frequency. A remote desktop feature of the AQMs permits the scripts to be interrupted, without use of crew time, so that the AQM runs could be coordinated with the mini-GSC sample acquisition. This paper will briefly describe the AQM technology, describe the validation requirements, and present the results from the AQM validation.
机译:2013年3月推出了两个空中质量监测器(AQMS)。使用不同的气相色谱柱的AQM单位同时运作,以准确地测量对船上空气质量评估重要的目标化合物。必须验证AQMS,这意味着他们必须证明他们能够准确地分析ISS氛围中的目标化合物,然后才能宣布准备运营使用。顾名思义,运营硬件可以使用,并将用于进行实时决策;因此,验证是必要的,以对生成的数据有信心。该监测站分别部署在三月下旬2013和验证是在2013年五月开始在飞行验证阶段,最小的6迷你抓取样品容器(迷你的GSC)的用的AQM样品分析几乎同时获得的。需要六个月来获取必要的迷你GSC-AQM配对以完成验证。在启动AQM之前建立的验证标准应用于每个化合物,而不是AQM单位。此外,验证包括远程位置中的AQM电池操作的结账。 AQMS使用脚本分析方案和频率自主操作。 AQMS的远程桌面功能允许脚本中断,无需使用船员时间,因此可以使用Mini-GSC示例采集协调AQM运行。本文将简要描述AQM技术,描述验证要求,并呈现来自AQM验证的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号