Development of an Air-Core Cylindrical HV Pulse Transformer

机译:开发空心圆柱形HV脉冲变压器

获取原文

摘要

The structure of an air-core cylindrical high voltage pulse transformer is relatively simple, but considerable attention is needed to prevent breakdown between transformer windings. Since the thickness of the spiral windings is on the order of sub-millimeter, field enhancement at the edges of the windings is very high. Therefore, it is important to have proper electrical insulations to prevent breakdown at the edges and to make the system compact. Major design parameters of the transformer are primary inductance of 170 nH, and output voltage of about 500 kV. The fabricated transformer is 45 cm in length and 30 cm in diameter. The fabricated transformer is tested up to 450 kV with a Marx generator. In this paper, we will discuss design and fabrication procedures, and preliminary test results of the air-core cylindrical HV pulse transformer
机译:空心圆柱形高压脉冲变压器的结构相对简单,但需要相当关注来防止变压器绕组之间的击穿。由于螺旋绕组的厚度是亚毫米的顺序,因此绕组边缘处的磁场增强非常高。因此,重要的是具有适当的电绝缘,以防止边缘处的击穿并使系统紧凑。变压器的主要设计参数是170 NH的初级电感,输出电压约为500 kV。制造的变压器长度为45厘米,直径为30厘米。使用Marx发电机测试制造的变压器最多450 kV。在本文中,我们将讨论设计和制造程序,以及空心圆柱形HV脉冲变压器的初步测试结果