An experimental study was carried out to investigate the heat transfer characteristics of an intermediate heat exchanger of the HTTR, using a full-size partial model and air as the fluid. The test model has 54 helically coiled tubes separated into three layer bundles and surrounding the center pipe. Radiate plates are installed between each bundle to promote heat transfer by radiation. A hot air (primary coolant), up to 300°C, flows upward on the shell side, and a cold air (secondary coolant) flows downward in the tubes. The heat transfer of the tube outside, due to forced convection, was obtained as a function of Re{sup}(0.56)Pr{sup}(0.3), and the ratio of the radiation heat transfer to the total transfer changed from 5 to 13% according to the temperatures, flow rates and the location of the tube bundles. The friction factor, depending on the tube arrangement, was proportional to Re{sup}(-0.14).
机译:进行实验研究,以研究HTTR的中间热交换器的传热特性,使用全尺寸的部分模型和空气作为流体。测试模型具有54个螺旋盘绕管,分为三层捆绑,围绕中心管。辐射板安装在每个束之间以通过辐射促进热传递。热空气(初级冷却剂),高达300℃,在壳侧向上流动,并且冷空气(二级冷却剂)向下流动。由于强制对流引起的管外部的传热作为RE {sup}(0.56)PR {sup}(0.3)的函数获得,并且辐射热传递与总转移的比率从5变为5根据温度,流速和管束的位置,13%。根据管装置的摩擦系数与RE {SUP}( - 0.14)成比例。