Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.