Adiabatic air-water two-phase flows in a commercial plate heat exchanger were visualized by thermal neutron radiography method as a nondestructive test in order to clarify liquid distributions. Liquid distributions in a single channel and a multichannel plate heat exchanger were investigated. From the results of a single channel, it was shown that gas phase tended to flow at the center of the net-like conduit and liquid fraction at the both side was higher. However, in the case of higher gas volumetric flux above 19 m/s, liquid distributions seemed to be homogenous. Measured average void fractions were lower than those by the homogenous model. On the other hand, from the results of a multichannel, it was shown that liquid distribution into the each channel strongly depended on inlet conditions. In the case of higher liquid flow rate and lower gas flow rate, liquid fraction became higher with the deeper channel due to larger liquid momentum. However, in the case of lower liquid flow rate and higher gas flow rate, the opposite tendency of liquid distribution was observed, that is to say, liquid fraction was lower with the deeper channel.
机译:为了澄清液体分布,通过热中子射线照相法将在商用板式换热器中的绝热空气-水两相流可视化为无损检测。研究了单通道和多通道板式换热器中的液体分布。从单通道的结果可以看出,气相倾向于在网状导管的中心流动,而两侧的液体分数较高。但是,在更高的气体体积通量高于19 m / s的情况下,液体分布似乎是均匀的。测得的平均空隙率低于均质模型。另一方面,从多通道的结果可以看出,进入每个通道的液体分配在很大程度上取决于入口条件。在较高的液体流速和较低的气体流速的情况下,由于较大的液体动量,随着通道越深,液体分数就越高。然而,在较低的液体流速和较高的气体流速的情况下,观察到相反的液体分布趋势,也就是说,随着通道的深,液体分数降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号