This paper presents an argument leading to estimate the minimal acceptable test sample size. In most cases the size of the test sample determines the number of possible test sites, since the other factors are usually fixed by test procedure. If the sample is too small, not enough data points are available and the resulting execution of an ISO standard or equivalent test, returns inaccurate and inprecise results. By use of a computer-based model, a 'single' optic is repeatedly tested and the results plotted versus sample size. This data is used to determine the curve of test accuracy as a function of sample size. The paper concludes with some 'rules of thumb' for determining the minimum acceptable test sample size for a given level of desired accuracy.
机译:本文提出了一个旨在估计最小可接受的测试样本大小的论点。在大多数情况下,测试样本的大小确定可能的测试站点的数量,因为其他因素通常通过测试程序来固定。如果样本太小,则没有足够的数据点,并且生成的执行ISO标准或等效测试,返回不准确和删除结果。通过使用基于计算机的模型,重复测试“单个”光学器,结果绘制了与样本大小。该数据用于根据样本大小的函数来确定测试精度的曲线。本文结束了一些“拇指规则”,用于确定所需精度的给定水平的最小可接受的测试样本大小。