The critical issues concerning the application of constant-temperature hot-film anemometry to hyper-sonic flow are reviewed and extended. Mass-flux static calibrations were conducted in a Mach 10 helium flow, while mass-flux and total-temperature static calibrations were made in a Mach 6 air flow. In addition, comparative hot-film/hot-wire turbulence measurements were made in a Mach 11 helium boundary layer to provide insight into the dynamic response of the hot film. The measurements indicate that substrate conduction "losses" dominate the static response of the hot-film probe, thus resulting in poor sensitivity to mass-flux and total temperature. Furthermore, it has been found that it is not possible to isolate mass-flux fluctuations at high overheat ratios for the current hot-film design.
机译:综述和延伸了关于恒温热膜风化至超声波流动的关键问题。在Mach 10氦气流中进行质量磁通静态校准,而Mach 6气流制造质量磁通和全温静态校准。另外,在马赫11氦边界层中制造比较热膜/热线湍流测量,以提供对热膜的动态响应的洞察。测量表明,基板传导“损失”主导了热膜探针的静态响应,从而导致对质量通量和总温度的敏感性差。此外,已经发现,对于电流的热膜设计,不可能在高过热比下隔离质量磁通波动。