首页> 外文会议>European conference on applied superconductivity >Thermal recovery of an inductive fault current limiter under different refrigeration conditions
【24h】

Thermal recovery of an inductive fault current limiter under different refrigeration conditions

机译:不同制冷条件下的电感故障电流限制器的热恢复

获取原文

摘要

We report new experimental results on the thermal behaviour of an inductive fault current limiter prototype based on a superconducting Bi-2223 tube. Our studies mainly focus on the recovery after a fault of relatively long duration (of the order of seconds). Tests have been made with the device submerged in a liquid nitrogen bath, and also in He gas and vacuum environments. We analyse the advantages of the increase of the limitation in He gas and vacuum environments as a consequence of the heating in the superconductor but also the problem of the very slow thermal recovery of the limiter, in the range of tens of minutes for a dissipated power around 30 W.
机译:我们在基于超导Bi-2223管的电感故障电流限制器原型的热行为报告新的实验结果。我们的研究主要关注持续时间相对较长的故障(秒的顺序)后恢复。用浸没在液氮浴中的装置进行测试,以及他的气体和真空环境。我们根据超导体中加热的结果分析了他气体和真空环境中限制的优点,而且在限制器的极慢热回收的问题中,在几十分钟的耗散功率的情况下大约30 W.