摘要

This paper describes a simple control method of voltage source active filters which compensate simultaneously the harmonics and reactive power absorbed by nonlinear loads. The calculation of active filter current references is based on the principle that the active component of load currents can be estimated by a PI regulator which controls the capacitor voltage of the active filter. By choosing appropriate parameters for the PI regulator, satisfactory static and dynamic performances can be obtained. The theoretical study is firstly confirmed by numerical simulation of a three-phase active filter-rectifier system and then by experimentation through a single-phase low-power model.
机译:本文介绍了一种简单的控制方法,电压源有源滤光器,其同时补偿非线性负载吸收的谐波和无功功率。有源滤波器电流参考的计算基于可以通过控制有源滤波器的电容器电压的PI调节器来估计负载电流的主动分量的原理。通过为PI调节器选择合适的参数,可以获得令人满意的静态和动态性能。首先通过三相有源滤波器整流系统的数值模拟来证实理论研究,然后通过单相低功率模型进行实验。