首页> 外文会议>IEEE Ultrasonics Symposium >Traveling Wave Driven Micro-Dispenser for CPU Cooling Application
【24h】

Traveling Wave Driven Micro-Dispenser for CPU Cooling Application

机译:用于CPU冷却应用的旅行波驱动微型分配器

获取原文

摘要

Micro-scale droplet was effectively applied to the CPU cooling. The PZT actuated porous membrane device which generating the micro-scale droplet with high latent heat of phase changes between liquid and vapor of water to achieve high heat transfer performance, it could remove heat from the CPU surface effectively for over 100 Watts as cooling system. And the device operating below the pressure of ambient environment prevents leakage as system fail. In order to design an efficient cooling device, it was important to study the dimensional effects of PZT actuator on the orifice plate vibration mode to pinch off droplet. The frequency and the applied voltage used to energize the PZT transducer were also important parameters that should be properly controlled in order to achieve the optimal liquid breakup conditions. The maximum flow rate approach 27 ml/min when operated at 50 kHz with 2.75 W, It also reveals the low noise and power consumption in the CPU cooling system.
机译:微尺寸液滴有效地应用于CPU冷却。 PZT致动多孔膜装置,其产生微尺寸液滴,具有高潜热的相变的液体和蒸汽之间的相变,实现高传热性能,它可以有效地从CPU表面去除100多个瓦特作为冷却系统。在低于环境环境压力下工作的设备可防止泄漏,因为系统失败。为了设计一种有效的冷却装置,重要的是研究PZT致动器对孔板振动模式的尺寸效应,以夹紧液滴。用于激励PZT换能器的频率和施加的电压也是应该适当控制的重要参数,以便实现最佳的液体分解条件。当使用2.75W的50kHz时操作时,最大流量接近27 ml / min,它还揭示了CPU冷却系统中的低噪声和功耗。