摘要

This paper reports on the progress of a research project intended to develop a method and instrumentation to detect, locate and characterize partial discharges and faults in the insulation of underground cable circuits. The method is non-destructive and applicable in-situ. It is designed to overcome the adverse effects of high ambient noise and high signal attenuation due to lossy semiconducting shields. Noise interference is reduced both by a judicious design of filters and through the use of digital deconvolution and noise reduction techniques. Methods are developed to generate a cable transfer function used in the process of enhancing and analyzing the PD signals. Results are shown from measurements performed in a noisy environment on a 600-ft 15 kV XLPE insulated cable. Testing of the method under actual field conditions is in progress.
机译:本文报告了研究项目的进展,旨在开发一种方法和仪器,以检测,定位和表征地下电缆电路绝缘中的部分放电和故障。该方法是非破坏性的,适用于原位。它旨在克服由于有损的半导体屏蔽引起的高环境噪声和高信号衰减的不利影响。通过使用数字去卷积和降噪技术,通过使用数字去卷积和降噪技术来减少噪声干扰。开发了方法以产生用于增强和分析PD信号的过程中使用的电缆传递函数。结果显示在600-FT 15 kV XLPE绝缘电缆上的嘈杂环境中进行的测量结果。在实际现场条件下测试方法正在进行中。