摘要

This poster is concerned with use of partial discharge monitoring to provide information about the condition of the insulation of electrical cables used for HVDC transmission systems. Electrical cables are among the most fundamental components of any electrical grid, from large subsea international interconnectors, to the ‘last mile’ providing consumers with their electrical supply. The size, cost and current carrying capability are the main considerations when designing and selecting a cable, and in this regard the insulation of these cables is as fundamental as the conductor. Partial discharge (PD) measurement is becoming increasingly vital in monitoring the condition of cable insulation, providing valuable information about the health of the insulation, and predicting when insulation is likely to fail. The majority of this PD monitoring is performed on cable operating under AC conditions, however, with the increasing use of high voltage DC links, for subsea, or long land-based connections provides motivation for the increased use of PD monitoring on cables operating under HVDC. However, despite the increased intensity of research into PD in HVDC cables, there are significant knowledge gaps, preventing the practical application of PD monitoring techniques to HVDC cables. This poster describes the initial stages of a project to partially address these gaps in knowledge, by seeking to obtain results from PD measurements on cables of different insulation types under both AC and DC conditions. From this, recommendations on the use of PD monitoring for HVDC cables, with emphasis on insulation type, are will be provided, as well as recommendations for future research at both an academic and industrial level. The poster will detail the results of the initial literature review, as well as the design for the planned experimentation, and test rig.
机译:该海报涉及使用局部放电监控来提供有关用于HVDC传输系统的电缆绝缘状况的信息。从大型海底国际互连器到为消费者提供电力的“最后一英里”,电缆是任何电网中最基本的组成部分。在设计和选择电缆时,尺寸,成本和电流承载能力是主要考虑因素,因此,这些电缆的绝缘与导体一样重要。在监视电缆绝缘状况,提供有关绝缘状况的有价值信息以及预测绝缘何时可能失效的方面,局部放电(PD)测量变得越来越重要。此PD监视的大部分是在交流条件下运行的电缆上进行的,但是,随着海底或长距离陆上连接中高压直流链路的使用的增加,为在HVDC下运行的电缆上的PD监视的增加提供了动力。但是,尽管对高压直流输电电缆中的局部放电的研究强度不断提高,但是仍然存在大量的知识空白,这阻碍了局部放电监测技术在高压直流电缆中的实际应用。该海报描述了通过寻求在交流和直流条件下对不同绝缘类型的电缆的局部放电测量结果来部分解决知识差距的项目的初始阶段。据此,将提供有关在高压直流输电电缆上使用局部放电监测的建议,重点是绝缘类型,以及在学术和工业层面上对未来研究的建议。海报将详细介绍最初的文献综述的结果,以及计划进行的实验和测试台的设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号