首页> 外文会议>IEEE International Conference on Smart Technologies for Power, Energy and Control >Efficiency improvement of a dual boost converter with zero voltage switching technique for battery charging application of a Solar Home Lighting System
【24h】

Efficiency improvement of a dual boost converter with zero voltage switching technique for battery charging application of a Solar Home Lighting System

机译:具有零电压开关技术的双升压转换器的效率提高太阳能家庭照明系统的电池充电应用

获取原文

摘要

Below paper presents development of the zero voltage switching(ZVS) dual boost converter for battery charging application in a solar home lighting system. Switching frequency is selected as 20 kHz. The resonant inductor and capacitor values have been designed at this switching frequency. The efficiency of hard switching dual boost converter varies from 88 to 90.5 % whereas for ZVS dual boost converter the efficiency is increased and is in the range of 91.2 to 94.2 % for a maximum load of 37 W. It is observed that there is the improvement in the maximum efficiency of the converter from 90.5 % to 96 % for a maximum load variation up to 37W as compared to hard switching technique.
机译:以下纸张介绍了在太阳能家庭照明系统中为电池充电应用的零电压开关(ZVS)双升压转换器的开发。切换频率选择为20 kHz。谐振电感器和电容值已经在该开关频率下设计。硬开关双升压转换器的效率在88到90.5%变化,而对于ZVS双升压转换器,效率增加,最大负载为37W的91.2%至94.2%。观察到有所改善与硬开关技术相比,转换器的最大效率为90.5%至96%,最大负载变化高达37W。