首页> 外文会议>Electrical Machines and Drives, 1993. Sixth International Conference on (Conf. Publ. No. 376) >Soft restart of an adjustable speed drive after a shortdisconnection without any mechanical speed sensor
【24h】

Soft restart of an adjustable speed drive after a shortdisconnection without any mechanical speed sensor

机译:短时间后对变频器进行软重启断开时没有任何机械速度传感器

获取原文

摘要

This high sensitivity of ASDs to power network disturbances iswell known by ASD manufacturers. They offer some mitigation strategiesagainst these disturbances. These strategies are based on `reducing asmuch as possible the effect of disturbances on the ASD behavior' orhaving a `ride-through capability in regards to disturbances' or a `softrestart'. Although some manufacturers seem to have mastered thesemitigation techniques, they have published almost nothing on thissubject to our knowledge. Therefore it is difficult to know whichmitigation strategies are used and what is the real level of ASDreliability in regards to disturbances. EDF has performed some researchin view of improving the reliability of ASDs under disturbances. Someresults of this study are presented in this paper. The effects ofvoltage dips and short supply interruptions on ASD behavior are firstexamined, then some mitigation control strategies are proposed
机译:ASD对电网干扰的高度敏感性是 由ASD制造商所熟知。他们提供了一些缓解策略 抵抗这些干扰。这些策略基于“减少为 干扰对ASD行为的影响尽可能 具有“抗干扰能力”或“软弱” 重新开始'。尽管一些制造商似乎已经掌握了这些 缓解技术,他们对此几乎没有发表任何文章 根据我们的知识。因此,很难知道哪个 使用缓解策略以及ASD的真实水平是多少 关于干扰的可靠性。法国电力公司进行了一些研究 鉴于在干扰下提高了ASD的可靠性。一些 本文介绍了这项研究的结果。的影响 首先是电压突降和电源短路对ASD的影响 检查,然后提出一些缓解控制策略