In this paper, a new control algorithm implemented on a three-phase three-wired shunt active power filler (SAPF) to compensate for harmonics and reactive power generated by unbalanced linearonlinear load is proposed. This algorithm is based on the instantaneous active current component id method, which was previously designed for the three-phase active power filter topology. In that design, the circuit performance was found unsatisfactory under unbalanced load. The proposed algorithm is therefore, motivated in order to solve such problems. Computer simulations results using power system blockset toolbox PSB of Matlab are given, which can confirm the feasibility and the performance of the new method. Improved results are obtained using the proposed control.
机译:本文提出了一种在三相三线并联有功功率滤波器(SAPF)上实现的新控制算法,以补偿线性/非线性负载不平衡所产生的谐波和无功功率。该算法基于瞬时有功电流分量i d 方法,该方法以前是为三相有源电力滤波器拓扑设计的。在该设计中,发现在不平衡负载下电路性能不能令人满意。因此,提出算法的动机是为了解决这些问题。给出了使用Matlab的电力系统模块集工具箱PSB进行的计算机仿真结果,可以证实该方法的可行性和性能。使用建议的控件可以获得改进的结果。