Feasibility Study on the Applicability of Clean Air in Gas-insulated DC Systems

机译:气体绝缘直流系统清洁空气适用性的可行性研究

获取原文

摘要

Gas-insulated DC systems offer significant advantages in terms of space requirements. The application of compact gasinsulated DC systems (DC GIS) is of particular interest for offshore platforms as well as in converter and transition stations in the context of long DC cable lines. A gas-insulated system for 550 kV rated DC voltage, based on SF6 technology, was developed, type-tested and introduced to the market. SF6 gas allows extremely compact dimensions of the system, but it requires very careful handling throughout the life cycle, as it is a gas with a high global warming potential (GWP). In order to contribute to an enhanced sustainability of the energy supply, the demand for SF6-free solutions is increasing since several years. A consistent solution is the application of the climate-neutral and fluorine-free insulating gas Clean Air (synthetic air with 80% nitrogen and 20% oxygen). A feasibility study examined the applicability of Clean Air technology for use in DC GIS of the voltage level of 320 kV, such as that used for grid access in the North Sea. In addition to a compilation of the requirements, the suitability for dielectric strength, mechanical strength at increased pressure and current carrying capacity / temperature rise was investigated. In addition to mechanical and thermal simulations as well as electric field calculations, high voltage tests were carried out to determine limit values. In basic tests on a GIS assembly, the influence of typical imperfections on the partial discharge activity at DC voltage was investigated, where SF6 served as a reference. In addition to a configuration with a tip on the inner conductor, the behaviour of free moving (conductive) particles was examined more in detail. Based on the given requirements, the feasibility of Clean Air application in DC GIS was confirmed.
机译:气体绝缘直流系统在空间要求方面具有显着的优势。紧凑型肠道直流系统(DC GIS)在长直流电缆线的背景下的离岸平台以及转换器和转换站中的应用特别感兴趣。基于SF6技术的550 kV额定直流电压的气体绝缘系统进行了开发,型式测试,并向市场介绍。 SF6气体允许系统的极其紧凑的尺寸,但在整个生命周期中需要非常仔细的处理,因为它是具有高全球变暖潜力(GWP)的气体。为了有助于提高能源供应的可持续性,自多年来对无效的解决方案的需求正在增加。一致的解决方案是应用气候中性和无氟绝缘气体清洁空气(具有80%氮气和20%氧气的合成空气)。可行性研究检测了清洁空气技术适用于320 kV的电压电平的DC GIS,例如用于北海的网格接入。除了汇编要求外,还研究了介电强度,增加压力和电流承载能力/温度升高时的机械强度的适用性。除了机械和热模拟以及电场计算之外,还执行高电压测试以确定极限值。在GIS组装的基本测试中,研究了典型缺陷对DC电压下的局部放电活动的影响,其中SF6用作参考。除了用内导体上具有尖端的构造之外,还详细检查了自由移动(导电)颗粒的行为。基于给定的要求,确认了DC GIS中清洁空气应用的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号