Based on data from Director General of POSTEL Indonesia, the prospect of Internet of Things in Indonesia reached 444 trillion with 400 million sensors connected. Various sectors are beginning to implement IoT as their automation systems such as industry, health, logistics, and agriculture. The proposed IoT system in this paper is using LoRa module transceiver and Arduino microcontroller. The data is sent through LoRa 915 MHz from 3 node sensor to the master. After data received in master LoRa, then the data is passed through to the server to be analyzed. Based on the outdoor measurement at 1 km, Rx LoRa obtain the RSSI below -100 dBm with average of PDR 58%. In indoor condition the RSSI value varies from -46 dBm to -85 dBm with PDR above 90%. In outdoor area the path loss exponent value in range 2.81-2.92. Meanwhile indoor area path loss exponent value in range 3.76-3.90 for all client.
机译:根据POSTEL Indonesia总干事的数据,连接4亿个传感器的印度尼西亚物联网的前景达到444万亿美元。各个行业开始将IoT用作其自动化系统,例如工业,卫生,物流和农业。本文提出的IoT系统使用LoRa模块收发器和Arduino微控制器。数据通过LoRa 915 MHz从3节点传感器发送到主机。在主LoRa中接收到数据后,该数据将传递到服务器进行分析。根据1 km处的室外测量,Rx LoRa获得低于-100 dBm的RSSI,平均PDR为58%。在室内条件下,PDR高于90%时,RSSI值在-46 dBm至-85 dBm之间变化。在室外区域,路径损耗指数值在2.81-2.92之间。同时,所有客户的室内区域路径损耗指数值在3.76-3.90范围内。