首页> 外文会议>Electromagnetic Compatibility Proceedings, 1997 International Symposium on >Measurement of voltage rise curves due to gap discharge usingcoupled transmission lines in distributed constant line system
【24h】

Measurement of voltage rise curves due to gap discharge usingcoupled transmission lines in distributed constant line system

机译:使用间隙测量由于间隙放电引起的电压上升曲线分布式恒定线路系统中的耦合传输线

获取原文

摘要

Very fast voltage rise curves due to gap discharge were examinedto discuss an EMI source. The measurement system consists of adistributed constant line system, because the voltage transients werevery rapid. A characteristic of the gap electrode, which has a matchedimpedance for the distributed constant line system, was investigated inthe frequency range below 5 GHz. The voltages of the power source in theexperiment were 510 V and 800 V because Paschen's law holds itsstability in the air condition. It was confirmed that the measurementmethod enables one to measure high speed voltage rise curves of about100 ps
机译:检查了由于间隙放电引起的非常快的电压上升曲线 讨论EMI来源。测量系统包括 分布式恒定线系统,因为电压瞬变是 非常快。间隙电极的特性,具有匹配的 分布式恒定线路系统的阻抗,在 低于5 GHz的频率范围。电源中的电压 实验是510 V和800 V,因为帕申定律 空调的稳定性。确认测量 该方法可使人测量大约为的高速电压上升曲线 100 ps