摘要

In connection with the monitoring of the insulation degradation oflarge power apparatus in order to predict their expected servicefailures, a statistical treatment, such as phase resolved partialdischarge analysis (PRPDA), has been established for the on-linemonitoring system during the past decades. However, this method hasshown some inconveniences to identify the nature of the PD source inpower apparatus. In this regard, a novel approach based on the chaoticanalysis (CAPD) is proposed describing the fundamental ideas, outcomesand different viewpoints from the conventional PRPDA. As a model for thepossible defects causing sudden failures in service, three types ofspecimen are prepared, and partial discharge signals, originating fromthose samples, are measured and analyzed by means of CAPD. Throughoutthis work, it seems that the correlation between the consecutive PDpulses, depending on the nature of PD, could be clarified by CAPD.Therefore, it could be considered that the nature of PD source can beidentified more distinctively when the CAPD is combined with PRPDA
机译:与监测绝缘的退化有关 大型动力设备,以预测其预期的服务 故障,进行统计处理,如相变偏 在线建立放电分析(PRPDA) 过去几十年的监控系统。但是,这种方法有 显示了一些不便之处,无法确定PD来源的性质 电力设备。在这方面,一种基于混沌的新颖方法 建议进行分析(CAPD),以描述基本思想,结果 和传统PRPDA的不同观点。作为模型 可能导致服务突然故障的缺陷,三种 样品被准备好,局部放电信号来源于 通过CAPD测量和分析这些样品。自始至终 这项工作,似乎是连续PD之间的相关性 CAPD可以根据PD的性质来确定脉冲。 因此,可以认为PD源的性质可以是 当CAPD与PRPDA结合使用时,可以更明显地识别

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号