In this paper, Direct methods to measure the Transfer Impedance (ZT) also known as Surface Transfer Impedance of HV-Cables are proposed which makes it easy to analyze and improve shielding properties. Proposed ZT direct methods are based on Current Probe (CP) and Capacitive Voltage Probe (CVP). Using these ZT direct methods, critical frequencies can be identified and preventive measures can be implemented. Proposed direct methods are verified by comparing measurement results with other renowned methods like Triaxial Method, Line Injection method and previously proposed Ground Plate Method. In these direct methods, main advantage is the ease of measurement i.e. without making any major variation in the cable under test.
机译:本文采用直接方法测量传输阻抗(Z T 提出了一种也称为HV电缆的表面转移阻抗的方法,该方法使分析和改善屏蔽性能变得容易。建议的Z T 直接方法基于电流探针(CP)和电容电压探针(CVP)。使用这些Z T 直接方法,可以确定关键频率并可以采取预防措施。通过将测量结果与其他著名的方法(如三轴方法,线注入方法和先前提出的接地板方法)进行比较,验证了所建议的直接方法。在这些直接方法中,主要优点是易于测量,即在被测电缆上没有任何重大变化。