The commonly used Transfer Impedance, Z_T, measurement methods forrnshielded cables and connectors for high voltage applications in Electric and Hybrid ElectricrnVehicles might be difficult to handle and reproducibility might be low. Alternative methodsrnto measure Z_T are required. In this article, the methods, Ground Plate Method and CapacitivernVoltage Probe Method are introduced. The methods do not require special setups andrncan handle even large cable-connector systems. Performance has been investigated by comparisonsrnto Z_T measurements using well established methods, i.e. Triaxial- and Line-rnInjection-Method. Performance and limitations of the proposed methods for both cable andrncable-connector systems are discussed. Measurement results were compared to analyticalrnformulas for Z_T. It could have been shown that accuracy of proposed, easier to apply andrnmore flexible alternative methods is in the same range as Triaxial- and Line-Injection-rnMethod.
机译:用于电气和混合动力车辆的高压应用的屏蔽电缆和连接器的常用传输阻抗Z_T测量方法可能难以处理,并且再现性可能很低。需要用于测量Z_T的替代方法。本文介绍了接地板法和电容电压探针法。该方法不需要特殊的设置,甚至可以处理大型电缆连接器系统。通过使用成熟的方法(即三轴注入法和线注入法)将Z_T测量值进行比较,研究了性能。讨论了针对电缆和电缆连接器系统的方法的性能和局限性。将测量结果与Z_T的解析公式进行比较。可以证明,所提出的,易于应用且灵活性更高的替代方法的精度与“三轴注入法”和“线注入法”在同一范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号