首页> 外文会议>International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management >Towards a unified low frequency Stability criterion for 15 kV / 16.7 Hz and 25 kV / 50 Hz railway power system
【24h】

Towards a unified low frequency Stability criterion for 15 kV / 16.7 Hz and 25 kV / 50 Hz railway power system

机译:为15 kV / 16.7 Hz和25 kV / 50 Hz铁路电力系统制定统一的低频稳定性标准

获取原文

摘要

Low frequency voltage instabilities of the AC railway networks are due to the interactions between modern traction vehicles and infrastructure. These instabilities can lead to a large amplitude modulation of the catenary voltage that can cause train power supply shut down or damage on traction equipment. This paper presents a straightforward method for determining the stability limit of a railway power system which is applicable to both 25 kV / 50 Hz and 15 kV / 16.7 Hz networks. This approach is the first step to define a unique stability criterion for both networks. The method is based on the stability limit curve of a traction chain plotted in the complex impedance plane (R, X). The validation of thismethod is performed through the use of a HIL (Hardware In the Loop) simulator.
机译:AC铁路网络的低频电压不稳定性是由于现代牵引车辆和基础设施之间的相互作用所致。这些不稳定性会导致悬链线电压的大幅度调制,从而导致火车电源关闭或牵引设备损坏。本文提出了一种确定铁路电力系统稳定极限的简单方法,该方法适用于25 kV / 50 Hz和15 kV / 16.7 Hz的网络。此方法是为两个网络定义唯一的稳定性标准的第一步。该方法基于在复阻抗平面(R,X)中绘制的牵引链的稳定性极限曲线。通过使用HIL(硬件在循环中)模拟器来执行此方法的验证。