Most of the insulation failure on induction motor stator windings occurs because of a short circuit between turns (turn-to-turn), which leads to total breakdown. Surge test on stator windings is one of the most common tests to detect symptoms of the fault. Usually, a surge test is applied to a stator winding without the rotor. This paper proposes an evaluation method for surge tests with the condition that the rotor remains attached. Two parameters are defined to identify the fault’s existence inside the rotor winding; those are Error Area Ratio (EAR) and Zero Crossing Point (ZCP). The rotors are rotated gradually, and the surge test is applied. EAR and ZCP values are calculated for each rotor position. Following that, all EAR and ZCP values of all rotor positions are added to become ΣEAR and ΣZCP. These two parameters are used to detect any damage to the windings. The result shows that by using these two parameters, the short circuit on the stator can be identified very sensitively, including as small as a half-percent (0.5%) short circuit of the total winding.
机译:感应电动机定子绕组的绝大部分绝缘故障是由于匝间短路(匝间)引起的,从而导致整体击穿。定子绕组的浪涌测试是检测故障症状的最常见测试之一。通常,对没有转子的定子绕组进行浪涌测试。本文提出了一种在转子保持连接的情况下进行浪涌测试的评估方法。定义了两个参数来识别转子绕组内部是否存在故障。这些是误差面积比(EAR)和零交叉点(ZCP)。转子逐渐旋转,并进行浪涌测试。计算每个转子位置的EAR和ZCP值。然后,将所有转子位置的所有EAR和ZCP值相加,成为ΣEAR和ΣZCP。这两个参数用于检测绕组是否损坏。结果表明,通过使用这两个参数,可以非常灵敏地识别定子上的短路,包括总绕组短路的0.5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号