Capacitive sensing technique was applied to detect multiphase-flow, grouting duct and many other fields. Some interesting phenomena were observed during the practical detection on grouting duct. The aim of this paper was to figure out these problems and provide guides for these issues. In this paper, 8 models of experiments were designed to determine the influence factors on the material of grouting duct, which caused the interesting phenomena. The experimental results show that three models, the water, steel bar-water, and steel bar-water-cement have influence of different degrees on the instability of measured results. The grounded wire of experimental specimens also could lead to the unstable measured values. Besides, the excessive angle of capacitive plates affect the measured results. The experimental results provide possible factors which caused the interesting phenomena and present the further research direction for the phenomena.
机译:电容传感技术被用于检测多相流,注浆管道和许多其他领域。在注浆管道的实际检测过程中观察到一些有趣的现象。本文的目的是找出这些问题并为这些问题提供指南。本文设计了8种实验模型来确定影响注浆管道材料的因素,从而引起了有趣的现象。实验结果表明,水,钢筋-水和钢筋-水-水泥三种模型对测量结果的不稳定性有不同程度的影响。实验样品的接地线也可能导致测量值不稳定。此外,电容板的过大角度会影响测量结果。实验结果提供了引起有趣现象的可能因素,并为该现象提供了进一步的研究方向。