首页> 外文会议>ASME Turbo Expo: Turbomachinery Technical Conference and Exposition >TURBINE VANE ENDWALL FILM COOLING EFFECTIVENESS OF DIFFERENT PURGE SLOT CONFIGURATIONS IN A LINEAR CASCADE
【24h】

TURBINE VANE ENDWALL FILM COOLING EFFECTIVENESS OF DIFFERENT PURGE SLOT CONFIGURATIONS IN A LINEAR CASCADE

机译:线性级联中不同吹气槽构型的涡轮叶片端壁膜冷却效率

获取原文

摘要

This study is concerned with the film cooling effectiveness of the flow issuing from the gap between the NGV and the transition duct on the NGV endwall, i.e. the purge slot. Different slot widths, positions and injection angles were examined in order to represent changes due to thermal expansion as well as design modifications. Apart from these geometric variations, different blowing ratios (BR) and density ratios (DR) were realized to investigate the effects of the interaction between sec-ondary flow and film cooling effectiveness. The experimental tests were performed in a linear scale-l cascade equipped with four highly loaded turbine vanes at the Institute of Fluid Mechanics and Fluid Machinery of the University of Kaiserslautern. The mainstream flow parameters were, with a reynolds number of 300,000 and a Mach number (outlet) of 0.6, set to meet real engine conditions. By using various flow conditioners, periodic flow was obtained in the region of interest (ROI). The adiabatic film cooling effectiveness was determined by using the Pressure Sensitive Paint (PSP) technique. In this context, nitrogen and carbon dioxide were used as tracer gases realizing two different density ratios DR =1.0 and 1.6. The investigation was conducted for a broad range of blowing ratios with 0.25 ≤ BR ≤ 1.50. In combination with 10 geometry variations and the aforementioned blowing and density ratio variations 100 single operating points were investigated. For a better understanding of the coolant distribution, the secondary flows on the endwall were visualized by oil dye. The measurement results will be discussed based on the areal distribution of film cooling effectiveness, its lateral spanwise as well as its area average. The results will provide a better insight into various parametric effects of gap variations on turbine vane endwall film cooling performance -notably under realistic engine conditions.
机译:这项研究涉及从NGV和NGV端壁上的过渡管道之间的间隙(即吹扫槽)发出的液流的薄膜冷却效果。检查了不同的缝隙宽度,位置和注入角度,以表示由于热膨胀和设计修改而引起的变化。除了这些几何变化之外,还实现了不同的吹塑比(BR)和密度比(DR),以研究二次流与薄膜冷却效率之间相互作用的影响。实验测试是在Kaiserslautern大学流体力学与流体机械研究所的配备有四个高负荷涡轮叶片的1级线性线性叶栅中进行的。主流流量参数设定为满足实际发动机条件,雷诺数为300,000,马赫数(出口)为0.6。通过使用各种流量调节器,可以在感兴趣的区域(ROI)中获得周期性的流量。绝热膜的冷却效率是通过使用压敏涂料(PSP)技术确定的。在本文中,使用氮气和二氧化碳作为示踪气体,实现了两种不同的密度比DR = 1.0和1.6。研究范围是0.25≤BR≤1.50的各种吹炼比。结合10种几何形状变化以及上述吹塑比和密度比变化,研究了100个单个工作点。为了更好地了解冷却液的分布,端壁上的二次流通过油性染料可视化了。将根据薄膜冷却效率的面积分布,横向跨度及其面积平均值来讨论测量结果。这些结果将使人们更好地了解间隙变化对涡轮叶片端壁膜冷却性能的各种参数影响,尤其是在实际发动机条件下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号