首页> 外文会议>Offshore technology conference >Vortex-Induced Vibration Effects of Production Risers in Proximity with Drilling Risers or Tendons
【24h】

Vortex-Induced Vibration Effects of Production Risers in Proximity with Drilling Risers or Tendons

机译:生产立管与钻井立管或肌腱在附近引起的涡流振动效应。

获取原文

摘要

This paper examines the effects of ocean currents on the vortex-induced vibration response of deepwater tubulars. such as umbilicals. production risers, tendons, and drilling risers, in proximity. This issue has received very little attention by the industry yet potentially has substantial importance to the design of deepwater tubulars and platforms. Experiments have been conducted in a current flume on tandem flexible tubulars with diameter ratios of 2:1 and 4:1. The smaller diameter tubular was placed in both the upstream and downstream positions, with the top and bottom locations spaced apart at three different distances. The tension was kept constant, but the current speed was varied. While both uniform flow and sheared flow tests were conducted, only the uniform flow tests are reported herein. The response modes varied from about 1-6, so that they were sufficiently high to easily allow both single mode and multiple mode responses, of which both were prevalent throughout the testing program. While all of the tests were conducted at low Reynolds numbers, the results can be thoughtfully translated to most field applications. The results describe the vibration and response characteristics of both the upstream and downstream tubulars for various configurations that were tested. Since a myriad of diameter ratios, separation distances, and flow velocities are possible with tubulars in the field, these tests have attempted to provide general insights into the responses of tandem tubulars with unequal diameters and. in some cases, offer guidance on limitations to the responses that can be used for offshore field designs.
机译:本文研究了洋流对深水管涡旋引起的振动响应的影响。例如脐带。生产立管,钢筋束和钻探立管附近。这个问题很少受到工业界的关注,但对于深水管和平台的设计可能具有实质性的重要性。在电流槽中对直径比为2:1和4:1的串联挠性管进行了实验。将较小直径的管放置在上游和下游位置,顶部和底部位置以三个不同的距离隔开。张力保持恒定,但当前速度有所变化。尽管进行了均匀流动和剪切流动测试,但此处仅报告了均匀流动测试。响应模式大约在1-6之间变化,因此它们足够高,可以轻松允许单模和多模响应,这两种响应在整个测试程序中都很普遍。尽管所有测试都是在低雷诺数下进行的,但可以将结果合理地转换为大多数现场应用。结果描述了在测试的各种配置下,上游和下游管材的振动和响应特性。由于在现场使用管子可以实现无数的直径比,分离距离和流速,因此这些测试试图对不等直径的串联管的响应提供一般性见解。在某些情况下,就可用于海上现场设计的响应限制提供指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号