首页> 外文会议>SPIE Medical Imaging Conference >CT investigation of patient-specific phantoms with coronary artery disease
【24h】

CT investigation of patient-specific phantoms with coronary artery disease

机译:冠状动脉疾病患者特定体模的CT检查

获取原文

摘要

Purpose: To develop coronary phantoms that mimic patient geometry and coronary blood flow conditions for CT imaging optimization and software validation. Materials and Methods: Five patients with varying degrees of coronary artery disease underwent 320-detector row coronary CT angiography (Aquilion ONE, Canon Medical Systems). The aorta and coronary arteries were segmented using a Vitrea Workstation (Vital Images). Patient anatomy was manipulated in Autodesk Meshmixer and 3D printed in Tango+, a flexible polymer, using an Eden260V printer (Stratasys). Phantoms were connected to a pump that simulates physiologic pulsatile flow waveforms, correlated with a simulated ECG signal. Distal resistance was optimized for all three coronary vessels until physiologically accurate flow rates and pressure were observed. Phantoms underwent coronary CT Angiography (CTA) using a standard acquisition protocol and contrast mixed in the flow loop. Image data from the phantoms were input to a CT-FFR research software and compared to those derived from the clinical data. Results: All five patient-specific phantoms were successfully imaged with CTA and the images were analyzed by the CT-FFR software. The phantom CT-FFR results had a mean difference of-5.4% compared to the patient CT-FFR results. Patient and phantom CT-FFR agreed for all three coronary vessels, with Pearson correlations r = 0.83, 0.68, 0.62 (LAD, LCX, RCA). Conclusions: 3D printed patient-specific phantoms can be manipulated through material properties, flow regulations, and a pulsatile waveform to create accurate flow conditions for CT based experimentation.
机译:目的:开发模仿患者几何形状和冠状动脉血流状况的冠状模型,以进行CT成像优化和软件验证。材料和方法:5例不同程度的冠状动脉疾病患者接受了320排螺旋CT血管成像检查(Aquilion ONE,佳能医学系统公司)。使用Vitrea工作站(重要图像)对主动脉和冠状动脉进行分割。使用Eden260V打印机(Stratasys)在Autodesk Meshmixer中操纵患者的解剖结构,并在Tango +(一种柔性聚合物)中进行3D打印。幻影连接到模拟生理脉动流波形的泵,该波形与模拟的ECG信号相关。对所有三个冠状动脉的远端阻力进行了优化,直到观察到生理上准确的流速和压力。幻影使用标准采集方案进行冠状动脉CT血管造影(CTA),并在流路中混合造影剂。来自幻像的图像数据被输入到CT-FFR研究软件中,并与从临床数据中获得的图像数据进行比较。结果:所有五个患者特定的体模均已成功通过CTA成像,并通过CT-FFR软件对其进行了分析。与患者的CT-FFR结果相比,幻影CT-FFR结果的平均差异为-5.4%。患者和体模CT-FFR均适用于所有三个冠状动脉血管,皮尔逊相关系数r = 0.83、0.68、0.62(LAD,LCX,RCA)。结论:可以通过材料特性,流量规则和脉动波形来操纵3D打印的患者特定体模,从而为基于CT的实验创建准确的流量条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号