Water tree generated in insulation parts of the XLPE (Cross Linked Polyethylene) cable is concerned as one of the causes of deterioration or breakdown. For the stable supply of electric power, the facilitated and accurate diagnosis technique is important to measure the deterioration of power cable. In our previous study, we proposed a residual charge measurement method using pulse voltage (charge larder method) and suggested that this method makes it possible the degradation position to measure more accurately than conventional methods. In this method, the deterioration signal is detected when the charge trapped at the tip of water tree is depolarized by the short time pulse voltage. However, quantitative evaluations have not been studied yet. In this paper, we investigated the residual charge behavior around the water tree under pulse voltage application and performed the numerical analysis using Maxwell-Wagner model.
机译:在XLPE(交叉连接聚乙烯)电缆的绝缘部件中产生的水树被涉及作为恶化或故障的原因之一。为了稳定的电力供应,促进和准确的诊断技术对于测量电力电缆的恶化非常重要。在我们以前的研究中,我们提出了一种使用脉冲电压(充电垃圾方法)的残余电荷测量方法,并建议该方法使得可能比传统方法更准确地测量劣化位置。在该方法中,当捕获在水树尖端的电荷被短时间脉冲电压去极化时检测到劣化信号。但是,尚未研究定量评估。在本文中,我们在脉冲电压应用下调查了水树周围的残余充电行为,并使用Maxwell-Wagner模型进行了数值分析。