OPTIMIZATION OF BORON METER MODEL

机译:硼米模型的优化

获取原文

摘要

In pressurized water reactors (PWRs), many boron meters have been used for continuous monitoring of boron concentration in reactor coolant. There exists a strong demand for accuracy improvement of the boron meters, so boron meter model optimization was studied in this work. A study was performed on fitting curve and a combined detector. With a combined detector composed of a high-level and a low-level sensitivity detector, the boron concentration error was decreased from 17.0 ppm (Boronline) to 1.2 ppm (Rational-1-2), which showed very great improvement for the boron meter accuracy.
机译:在压水反应堆(PWR)中,许多硼计已用于连续监测反应堆冷却剂中的硼浓度。对提高硼计的精度存在强烈的需求,因此在这项工作中对硼计模型的优化进行了研究。对拟合曲线和组合检测器进行了研究。使用由高灵敏度和低灵敏度检测器组成的组合检测器,硼浓度误差从17.0 ppm(硼)降低到1.2 ppm(Rational-1-2),这对硼仪显示出很大的改进准确性。